Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.046
Filtrar
1.
Clin Oral Investig ; 28(5): 255, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630185

RESUMO

OBJECTIVES: To evaluate the trueness of the digital maxillary occlusal records in comparison with the conventional records for the fabrication of complete-arch implant-supported fixed prostheses. MATERIALS AND METHODS: This randomized controlled clinical trial followed the recommendations of the CONSORT statement. Twenty participants who used a mandibular interim complete-arch fixed prosthesis and conventional complete maxillary dentures were included in the study. The participants were randomized into two types of maxillary occlusal records: conventional (COR) and digital (DOR) (TRIOS; Shape A/S). After fabricating the prostheses, the distribution and number of occlusal contact points, and the time taken to obtain the maxillary occlusal record and work model were evaluated. Descriptive analysis was used to evaluate the distribution of occlusal contact points. The Wilcoxon test was employed for assessing the number of occlusal contact points, while the Mann-Whitney U test was used for the time taken to obtain the working casts and the maxillary occlusal record and occlusal adjustment times (p < 0.05). RESULTS: There was a similarity in the jaw relation recording methods regarding the distribution of occlusal contact points. There was no difference in the number of occlusal contact points between the anterior (p = 0.439) and posterior (p = 0.227) teeth. No relationship was observed between the distribution and number of occlusal contact points (COR, p = 0.288; DOR, p = 0.183). DOR required less occlusal and clinical adjustment time, on the other hand more laboratory and total workflow time than COR (p < 0.001). CONCLUSION: The DOR may be an option for obtaining the functional space necessary for the assembly of teeth in complete-arch implant-supported fixed prostheses; however, it requires more working time. CLINICAL RELEVANCE: The digital occlusal recording method can be used to assess the interocclusal space for the virtual tooth setup of a complete-arch implant-supported fixed prosthesis.


Assuntos
Implantes Dentários , Humanos , Prótese Total , Registro da Relação Maxilomandibular , Laboratórios , Mandíbula
2.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(1): 67-74, 2024 Feb 01.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38475953

RESUMO

OBJECTIVES: This clinical study aimed to evaluate the accuracy of a fully digital technique for measuring sagittal condylar inclination (SCI), as well as validating whether differences existed between the left and right SCI values of the same participant, to provide a reference for clinical practice. METHODS: Ten participants with good occlusal relationship and normal temporomandibular joint were recruited. Three methods were used to measure the SCI values of the participants, namely, A (mechanical facebow transferring and mechanical articulator-based measuring method with physical protrusive interocclusal registration), B (face scan-based virtual facebow and virtual articulator-based measuring method with digital protrusive interocclusal registration), and C (jaw motion tracking system-based measuring method). With the group subjected to methods A and C as the control, the SCI values obtained by the three methods were statistically analyzed. The left and right SCI values of the same participant were also compared. RESULTS: The left and right SCI values measured by method A were 41.70°±7.09° and 42.80°±8.62°, those by method B were 35.09°±12.49° and 37.63°±12.10°, and those by method C were 39.43°±8.72° and 38.45°±6.91°. No significant difference existed among the SCI values measured by the three methods (P>0.05). Meanwhile, no statistical difference existed between the SCI values on the left and right sides of the same participant (P>0.05). CONCLUSIONS: The accuracy of the virtual facebow and digital protrusive occlusal registration based SCI measuring method was the same as that of mechanical facebow based and jaw motion tracking system-based methods. The SCI values on the left and right sides of the same participant were similar. Clinically, an appropriate SCI measurement and setting strategy can be selected based on the actual situations.


Assuntos
Côndilo Mandibular , Articulação Temporomandibular , Humanos , Registro da Relação Maxilomandibular/métodos , Articuladores Dentários , Aparelhos de Tração Extrabucal
3.
Clin Oral Investig ; 28(4): 233, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556612

RESUMO

OBJECTIVES: Reconstruction of a three-dimensional jaw position determined by a bite recording is an important aspect of prosthetic therapy. Different materials are used for this purpose. In the dental technical workflow, recordings are used to mount a lower jaw cast in a patient-like spatial position relative to the upper jaw cast. We evaluated the accuracy of positioning under the influence of different jaw positions and materials. MATERIALS AND METHODS: In an experimental setup, comprising an articulator, a pair of metal casts, and an optoelectronic measurement system, the spatial position of the incisal point and two condylar points were measured. To evaluate the accuracy of repeated repositioning of casts in the technical workflow, 324 measurements were taken from 108 recordings, consisting of silicone bite-stops made of addition curing silicone with 95 shore hardness, acrylic wafers, and wax recordings. The recordings were obtained in four jaw relations differing in vertical and protrusive components. RESULTS: Of the three materials/material combinations examined, silicone showed the most consistent results across all measurements, followed by the acrylic wafer system, and then wax recordings. Generally, recordings with smaller gaps between the jaws and no protrusive components showed greater deviations compared to jaw positions with greater protrusion and higher vertical dimensions. CONCLUSIONS AND CLINICAL RELEVANCE: To achieve reliable model mounting with high accuracy, recordings should include the use of a frontal jig and four small recording platelets made of silicone, especially if only a slight elevation of the vertical dimension is needed.


Assuntos
Articuladores Dentários , Mandíbula , Humanos , Registro da Relação Maxilomandibular/métodos , Dimensão Vertical , Silicones
4.
BMC Oral Health ; 24(1): 345, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38500122

RESUMO

BACKGROUND: Finding and registering the maxillary-mandibular jaw relation is crucial in dental practice. Several comparative studies have been conducted to investigate the reproducibility and accuracy of techniques for determining the centric relation (CR) position of the mandible. The aim of our study was to determine which of seven different CR determination methods had the smallest deviation from the theoretical zero with the help of a digital mandibular motion analyser. The chosen theoretical zero position, the maximal intercuspal position (MIP), is the most reproducible and widely used position. METHODS: Thirty-four volunteers (24 females and 10 males) with a mean (SD) age of 29.1 (± 7.3) years with a negative history of temporomandibular disorder (TMD) participated in the study. A digital mandibular motion analyser was used to register the condylar position after the use of each technique for the determination of CR. The calibration was performed to the maximal intercuspal position (MIP) for each volunteer. The investigated techniques were (A) the gothic arch tracer, (B) the adduction field method, (C) Dawson's bimanual manipulation, (D) the patient placing the tongue tip on the palatal rugae, (E) the patient placing the tongue tip to the border of the hard and soft palate, (F) the patient actively pulling the chin backwards, and (G) the examiner pushing the patient's chin back. RESULTS: The position of the mandibular condyle was illustrated in a three-dimensional coordinate system, where the origin represented the MIP. Among the seven methods examined, five showed significant deviations compared to the MIP. Among these, two methods resulted in posterior deviation of the condyles. Methods C and E coincided with the MIP in all directions. CONCLUSIONS: Within the limitations of our study, we found that the smallest deviations from our theoretical zero (MIP) among the investigated centric relation determining methods were obtained with the bimanual mandibular manipulation technique derived from Dawson and the placement of the tongue tip on the border of the hard and soft palate (linguomandibular homotrophy theory).


Assuntos
Mandíbula , Côndilo Mandibular , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Relação Central , Reprodutibilidade dos Testes , Queixo , Registro da Relação Maxilomandibular
5.
J Dent ; 143: 104889, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38369252

RESUMO

OBJECTIVES: To evaluate dynamic condylar positions by integrating mandibular movement recording data and cone-beam computed tomography (CBCT) and to investigate its accuracy via dynamic model experiments. METHODS: A polyvinyl chloride skull model was utilized. A robot arm was used to operate the mandible to perform mouth opening, closing, protrusion, and lateral movements. A recording device, worn on the skull, was used to record the dynamic process and an optical position tracking (OPT) system was used to simultaneously trace the movements. A self-developed software module was used to evaluate the dynamic condylar position by integrating the dynamic tracing data and a virtual skull model derived from CBCT images. Errors were defined as differences between the dynamic coordinates of six landmarks around the condylar area derived from the software module (test) and OPT system (gold standard). RESULTS: The condylar position errors were 0.76 ± 0.31, 0.55 ± 0.15, and 0.68 ± 0.23 mm for mouth opening, bilateral, and protrusion movements, respectively. Furthermore, the errors for small, moderate, and large mouth opening movements were 0.62 ± 0.19, 0.69 ± 0.29, and 0.94 ± 0.31 mm, respectively. The errors for all movements, except for large mouth opening, were significantly less than 1 mm (P < 0.05). The error was not different from 1 mm in the large mouth opening movement (P > 0.05). CONCLUSIONS: Our developed method of achieving dynamic condylar position by integrating mandibular movement recording data and CBCT images is clinically reliable. CLINICAL SIGNIFICANCE: This study proved the reliability of evaluating dynamic condylar position using a commercial dynamic recording instrument and CBCT images.


Assuntos
Côndilo Mandibular , Articulação Temporomandibular , Articulação Temporomandibular/diagnóstico por imagem , Côndilo Mandibular/diagnóstico por imagem , Reprodutibilidade dos Testes , Registro da Relação Maxilomandibular , Mandíbula/diagnóstico por imagem
6.
J Dent ; 142: 104833, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38199326

RESUMO

OBJECTIVES: This study aimed to assess the effectiveness of patient-specific motion in restoring anterior guidance and to investigate the influence of occlusal plane position within a virtual articulator on the design of the anterior guide slope for incisors. METHODS: Twenty participants' intraoral scan, occlusal plane position, and jaw motion data were recorded. The maxillary anterior teeth were virtually prepared, and the crowns were designed based on average virtual articulator (AVR), personalized virtual articulator (ART), and patient-specific motion (PSM). The anterior guide slope of maxillary central incisors (S1, S2, Sc, Sp) and the mesio-distal angle (MDA) of the canine of prostheses were compared to that of natural teeth (NAT). One-Way ANOVA was utilized to evaluate the effectiveness of the three methods in restoring the anterior guidance of maxillary anterior teeth. RESULTS: The comparison of Sp and MDA showed no significant difference between the PSM and NAT groups (p > 0.05). However, Sp of the ART group was significantly smaller, while MDA was higher than that of the NAT group (p < 0.05). Sp did not differ significantly (p > 0.05) when the angle of the occlusal plane (AOP) was small. As the AOP increased, Sp of the ART and AVR groups were significantly smaller than that of the NAT group (p < 0.05). With a large AOP, Sp of the ART group was notably smaller than that of the NAT group (p < 0.05), while there was no significant difference between the AVR and NAT groups (p > 0.05). CONCLUSIONS: Occlusal design based on patient-specific motion proved more effective in restoring natural anterior guidance. The anterior guidance of prostheses designed using a virtual articulator was influenced by occlusal plane position. CLINICAL SIGNIFICANCE: The utilization of a jaw motion tracer facilitated the transfer of personalized occlusal plane positions and recorded jaw motion, which can be integrated into the digital prosthetic workflow for virtual occlusion adjustment. Occlusal design based on patient-specific motion more effectively restored lingual guidance of maxillary anterior crowns.


Assuntos
Oclusão Dentária , Incisivo , Humanos , Registro da Relação Maxilomandibular , Maxila , Articuladores Dentários , Desenho Assistido por Computador
7.
J Esthet Restor Dent ; 36(5): 710-722, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38131436

RESUMO

OBJECTIVE: The purpose of this article was to introduce a method for the digital application of three-dimensional (3D) diagnosis and treatment with a virtual articulator and 3D data. CLINICAL CONSIDERATION: With the use of cone-beam computed tomography (CBCT) and intraoral and facial scans, we can create a virtual articulator and evaluate the mandibular position in maximum intercuspation and centric-related occlusion for the patient with an unstable occlusion and temporomandibular disorders (TMD). Based on this, we treated a case using a digital mandibular position indicator (MPI) and fabricated a stabilization splint using a 3D printer. This approach eliminates the traditional impression or model mounting process and the analog face bow transfer. Furthermore, the design of the stabilization splint is accomplished using software. CONCLUSIONS: The approach outlined in this article offers the potential for a digital diagnosis and treatment process by seamlessly integrating CBCT, intraoral scans, and facial scans with a high degree of accuracy. This may enhance precision in diagnosis and treatment planning, especially for patients with complicated TMD, in addition to facilitating effective communication with orthodontic patients who require thorough attention. CLINICAL SIGNIFICANCE: Utilizing a virtual articulator and digital MPI for the occlusal evaluation of patients with TMD and unstable occlusion makes it possible to diagnose and analyze the occlusal condition accurately. This approach also allows for precision and efficiency in treatment.


Assuntos
Articuladores Dentários , Imageamento Tridimensional , Humanos , Registro da Relação Maxilomandibular/métodos , Imageamento Tridimensional/métodos , Modelos Dentários , Oclusão Dentária , Tomografia Computadorizada de Feixe Cônico/métodos
8.
J Indian Prosthodont Soc ; 23(4): 322-334, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37861609

RESUMO

Aim: The aim of this systematic review and meta-analysis was to determine the accuracy of different methods of measuring horizontal condylar guidance (HCG) angle in comparison with extraoral Gothic arch tracing for completely edentulous patients. Settings and Design: This was a systematic review and meta-analysis following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Materials and Methods: Two reviewers searched the EBSCOhost, Cochrane Library, and PubMed/MEDLINE databases and the Google Scholar search engine for in vivo studies, randomized controlled trials, cross-sectional studies, and quasi-experimental studies published from January 2005 to December 2022 on various other methods of determining HCG angle in completely edentulous patients compared with extraoral Gothic arch tracing method. Statistical Analysis Used: Meta-analysis was conducted from the reported quantitative data. Results: A total of 513 articles were obtained from different electronic databases, of which 22 studies were included for qualitative synthesis and 20 studies were included for meta-analysis. For the right side, a statistically significant difference was observed for panoramic radiograph (P < 0.05, pooled mean difference = 5.08 [2.17, 7]) and cephalogram (P < 0.05, pooled mean difference = 10.65 [8.81, 12.49]), whereas no statistically significant difference was observed for cone-beam computed tomography (CBCT) (P = 0.41, pooled mean difference = 4.39 [-6.10, 14.87]) and protrusive interocclusal wax record (P = 0.92, pooled mean difference = -0.45 [-9.62, 8.72]) as compared with extraoral Gothic arch tracing method. For the left side, a statistically significant difference was observed for panoramic radiograph (P < 0.05, pooled mean difference = 5.07 [1.95, 8.18]) and cephalogram (P < 0.05, pooled mean difference = 10.24 [8.65, 11.83]), whereas no statistically significant difference was observed for CBCT (P = 0.31, pooled mean difference = 4.05 [-3.74, 11.84]) and protrusive interocclusal wax record (P = 0.72, pooled mean difference = -1.21 [-7.86, 5.43]) as compared with extraoral Gothic arch tracing method. Conclusion: The cephalogram and panoramic radiograph obtained higher HCG angles in completely edentulous patients than extraoral Gothic arch tracing.


Assuntos
Boca Edêntula , Humanos , Registro da Relação Maxilomandibular/métodos , Estudos Transversais , Boca Edêntula/diagnóstico por imagem , Radiografia Panorâmica , Tomografia Computadorizada de Feixe Cônico
9.
J Contemp Dent Pract ; 24(6): 403-408, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37534507

RESUMO

AIMS: A clinical study to compare the horizontal condylar guidance using protrusive interocclusal records, orthopantomography (OPG), and cone-beam computed tomography (CBCT) in edentulous patients. SUBJECTS AND METHODS: Thirty-six edentulous subjects were selected as per predetermined criteria. Horizontal condylar guidance was recorded using protrusive interocclusal records (PIR), OPG, and CBCT for each patient. The PIR were obtained using extraoral Gothic arch tracers to program the Hanau articulator. The horizontal condylar guidance angles (HCGAs) were digitally constructed using appropriate software along the posterior slope of articular eminence for all radiographs. The collected data were recorded, tabulated, and statistically analyzed. RESULTS: The condylar guidance angle values were tested for significance to compare the different angles. The correlation of HCGA measurements on both sides between the three groups was analyzed. The PIR and OPG methods (p = 0.001), as well as the OPG and CBCT methods (p = 0.001), show substantial differences on both sides. On the contrary, the PIR and CBCT methods did not differ significantly (p = 0.11). CONCLUSION: Cone-beam computed tomography is as reliable and accurate as the clinical method. A significant correlation exists between the clinical method and CBCT. It can be used as a dependable adjunct to the clinical method of HCGA measurement. CLINICAL SIGNIFICANCE: Cone-beam computed tomography can overcome the shortcomings of the conventional clinical methods to determine the accurate horizontal condylar guidance angulation measurement. It is safer with minimum discomfort and wastage of time for the patients.


Assuntos
Boca Edêntula , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Radiografia Panorâmica , Registro da Relação Maxilomandibular/métodos , Côndilo Mandibular/diagnóstico por imagem , Boca Edêntula/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico
10.
Ann Afr Med ; 22(3): 316-320, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37417019

RESUMO

Background and Purpose: During complete denture fabrication making Interocclusal records plays an integral role to obtain the condylar guidance value. The study was conducted to compare the protrusive condylar guidance registration by two interocclusal recording materials-Quick setting plaster and Luxabite®(bisacrylic composite) in semi adjustable articulator for completely edentulous patients. Methodology: Maxillary and Mandibular casts of the completely edentulous patients were mounted in Hanau®Wide Vue articulator. The Quick setting plaster and Luxabite®(bisacrylic composite) was used as interocclusal recording materials to program the protrusive condylar guidance angles in the articulators. Results: The protrusive condylar guidance values registered in the articulator for the different interocclusal records were tabulated and statistically analyzed.. The mean protrusive condylar guidance values registered in the articulator was compared with two parameters obtained from the radiographic tracings -- the protrusive condylar path angle obtained with Quick setting plaster and Luxabite with the inclination of articular eminence to the Frankfort horizontal plane. Conclusion: From the study it was concluded that the Luxabite®(bisacrylic composite) material demonstrated better reproducibility of protrusive condylar guidance registration.than the Quick setting plaster.


Résumé Contexte et objectif: Pendant la fabrication complète de la prothèse de prothèse, la fabrication des enregistrements d'interoccluse joue un rôle essentiel pour obtenir la valeur de guidage condylien. L'étude a été réalisée pour comparer l'enregistrement de guidage condylien en saillie par deux matériaux d'enregistrement interocclusal - Platter en plâtre et Luxabite® (composite bisacrylique) dans un articulateur semi-réglable pour les patients complètement édentés. Méthodologie: Les moulages maxillaires et mandibulaires des patients complètement édentés ont été montés dans l'articulateur de Hanau® à large de Vue. Le plâtre à réglage rapide et Luxabite® (composite bisacrylique) ont été utilisés comme matériel d'enregistrement interocclusal pour programmer les angles de guidage condyliennes en saillie dans les articulateurs. Résultats: Les valeurs de guidage condylien en saillie enregistrées dans l'articulateur pour les différents enregistrements interocclusaux ont été tabulées et analysées statistiquement. Les valeurs de guidage condyliennes en protruments moyennes enregistrées dans l'articulateur ont été comparées à deux paramètres obtenus à partir des tracages radiographiques - le protruments de l'angle de trajectoire condylien obtenu avec un plâtre rapide et luxabite avec l'inclinaison d'une éminence articulaire au plan horizontal de Frankfort. Conclusion: D'après l'étude, il a été conclu que le matériau Luxabite® (composite bisacrylique) avait démontré une meilleure reproductibilité de l'enregistrement de guidage condylien en saillie que le plâtre de réglage rapide. Mots-clés: Guidage condylien, édenté, facebow, plan horizontal de Frankfort, dossier interocclusal, radiographie céphalométrique latérale, guidage condylien en saillie, articulateur semi-réglable.


Assuntos
Mandíbula , Côndilo Mandibular , Humanos , Côndilo Mandibular/diagnóstico por imagem , Registro da Relação Maxilomandibular , Reprodutibilidade dos Testes , Cimentos de Resina
11.
Indian J Dent Res ; 34(1): 30-35, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37417053

RESUMO

Objective: This study aimed to evaluate the validity and reliability of three bite registrations on articular disc position in temporomandibular disorder patients using magnetic resonance imaging (MRI). Materials and Methods: Fifteen clinically symptomatic and orthodontically untreated temporomandibular disorder patients within the age range of 17-40 years (mean age: 28.5 years) were examined. Each patient was subjected to three bite registrations, namely maximum intercuspation, initial contact bite and Roth power centric bite, and evaluated with MRI. Results: On the right side, the mean vertical and horizontal measurement values of the point in the most posterior aspect of the posterior band of the articular disc in relation to horizontal reference line (HRL) and vertical reference line (VRL) in the sagittal view in the Roth power centric bite were lesser (2.720 ± 1.239 mm and 2.380 ± 1.185 mm, respectively), in comparison with the other two bites, and on the left side too, it was lesser in the Roth power centric bite (2.293 ± 0.979 mm and 2.360 ± 1.078 mm, respectively), when compared to the other two bites. Statistical analysis also showed the significance of Roth power centric bite over the other two bites. Conclusions: Favourable articular disc positional changes were observed in the Roth power centric bite followed by the initial contact bite and that maximum disc recapture was observed in most patients with the Roth power centric bite rather than in initial contact bite and maximum intercuspation positions. The Roth power centric bite could be assumed to be the ideal method for articulation and fabrication of gnathological splints for treating patients with temporomandibular disorders.


Assuntos
Côndilo Mandibular , Transtornos da Articulação Temporomandibular , Adolescente , Adulto , Humanos , Adulto Jovem , Relação Central , Registro da Relação Maxilomandibular , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Articulação Temporomandibular , Transtornos da Articulação Temporomandibular/diagnóstico por imagem
12.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 41(3): 254-259, 2023 Jun 01.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-37277790

RESUMO

OBJECTIVES: This study aimed to compare the effects of virtual adjustment on occlusal interferences in mandibular posterior single crown and three-unit bridge restorations by using the mandibular movement track and the movement parameters of a virtual articulator. METHODS: Twenty-two participants were recruited. Digital casts of the maxillary and mandibular arches were obtained using an intraoral scanner, and the jaw registration system was used to record the data of the mandibular movement track and the movement parameters of the articulator. Four kinds of restorations with 0.3 mm occlusal interferences were designed with dental design software. In particular, single crowns were designed for teeth 44 and 46, whereas three-unit bridges were designed for teeth 44-46 and 45-47, and the corresponding natural teeth were virtually extracted. Virtual adjustment of the restorations was performed using two dynamic occlusal recordings, namely, the mandibular movement track and the movement parameters of the virtual articulator. A reverse-engineering software was used to measure the root-mean-square of the three-dimensional deviation of the occlusal surfaces between natural teeth and the adjusted restorations. The differences between the two methods of virtual-occlusion adjustment were compared and analyzed. RESULTS: For the same group of restorations, the three-dimensional deviation of the mandibular movement track group were lower than those of the virtual articulator group, and the differences were statistically significant (P<0.05). For the four groups of restorations adjusted by the same method, the three-dimensional deviation of the 46-tooth single crown was the largest and the smallest three-dimensional deviation was that of the 44-tooth single crown. Statistical differences existed between the 44-tooth single crown and the other groups (P<0.05). CONCLUSIONS: For the occlusal design of posterior single crown and three-unit bridge, the mandibular movement track could be a more effective approach to virtual occlusal adjustment than the movement parameters of the virtual articulator.


Assuntos
Articuladores Dentários , Ajuste Oclusal , Humanos , Boca Edêntula , Registro da Relação Maxilomandibular , Software
13.
J Dent ; 135: 104583, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37331577

RESUMO

OBJECTIVES: The aim of this study was to clinically evaluate the accuracy of a digital axiographic recording system in tracing the sagittal condylar inclination. METHODS: An axiographic examination that records the sagittal condylar path during protrusive/retrusive movement was performed on ten patients. Each subject was registered five different times by two different systems: 1) the Cadiax Gamma Diagnostic 4 computerized system as the control; 2) the Zebris Jaw Motion Analyser+  Optic System as the tested digital axiographic recording system. The records obtained allow to calculate the kinematic terminal transverse horizontal axis and the sagittal condylar inclination (SCI) at 3 and 5 mm along the pro-retrusive path. A linear mixed model was used to analyze if there was a statistically significant difference between the two systems. RESULTS: The mean left SCI value recorded by Zebris system were 49.81 ± 10.64° at 3 mm, 48.10 ± 11.04° at 5 mm, while the values recorded by Gamma system were 55.16° at 3 mm, 52.18° at 5 mm. The mean right SCI value recorded by Zebris system were 54.53 ± 10.26° at 3 mm, 51.85 ± 8.55° at 5 mm, while the values recorded by Gamma system were 49.68° at 3 mm, 48.23° at 5 mm. Linear mixed model showed no significant statistical difference between the two systems. CONCLUSIONS: Based on preliminary results, the Zebris Jaw Motion Analyzer+ Optic System demonstrates comparable accuracy to the Cadiax Gamma Diagnostic 4 when measuring sagittal condylar inclination. CLINICAL SIGNIFICANCE: The digital axiographic recording system enables to evaluate sagittal condylar inclination and to adjust virtual articulators in a digital workflow.


Assuntos
Côndilo Mandibular , Movimento , Humanos , Côndilo Mandibular/diagnóstico por imagem , Registro da Relação Maxilomandibular/métodos , Articuladores Dentários , Fenômenos Biomecânicos
14.
Clin Oral Investig ; 27(7): 4039-4050, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37126145

RESUMO

OBJECTIVE: Whether it is primarily the spine that reacts with pain to the negative consequences of everyday stress and possibly the temporomandibular system as a result (ascending chain), or whether incorrect stress in the dental area has an influence on body geometry (descending chain), is still a controversially discussed topic. The aim of this study is to investigate possible relationships between constitutional, axiographic, and dental parameters with upper body posture. MATERIAL AND METHODS: A total of 106 subjectively healthy women between 31 and 40 years of age voluntarily participated in this study. Data collection was done by filling out a questionnaire with constitutional and anamnestic parameters and by evaluating orthodontic casts, axiographic measurements, and video raster stereographic measurements. These data were analyzed using correlations and group comparisons, with the significance level set at p ≤ 0.05. RESULTS: Positive correlations were shown between the constitutional factors of body weight and BMI and the lumbar bending angle (p = 0.01), the kyphosis angle (p = 0.001), and lordosis angle (weight p = 0.05; BMI p = 0.03). In the cast analysis, regardless of the direction of the midline shift (left/right/none), a left lateral tilt can be seen which is greatest at 2.12° with a left midline shift. In addition, the elevated pelvic side correlates with the side of the displacement of the jaw, with the stronger manifestation being on the left side. With a vertical anterior bite in the normal range, the kyphosis angle is 48.09°, while with a deep bite, it is 60.92°, and with an open bite, it is 62.47°; thus, the group in the normal range differs significantly (p = 0.01) from the other two. The greater the protrusion, the smaller the sagittal plane angles (kyphosis angle, lumbar bending angle, each p = 0.03), and the more dorsal the posture (p = 0.04). The lordosis angle differs significantly (p = 0.001) between the group of subjects with a protrusion in the normal range (52.34°) and the group with an increased advancement of the mandible (41.79°). CONCLUSION: There is a correlation between body weight, BMI, midline shift, and protrusion, as well as the vertical anterior step and upper body posture in women between 31 and 40 years of age. Interdisciplinary functional examinations of the temporomandibular musculature, and also sustained orthodontic treatment, can contribute to an improvement in upper body posture.


Assuntos
Cifose , Lordose , Humanos , Feminino , Adulto , Postura , Registro da Relação Maxilomandibular , Peso Corporal
15.
J Esthet Restor Dent ; 35(7): 1068-1076, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37132534

RESUMO

OBJECTIVE: This technique aimed to describe a fully digital workflow to register maxillomandibular relation for fixed prosthetic rehabilitation. CLINICAL CONSIDERATIONS: Mandibular kinematics could be reproduced in a four-dimensional (4D) virtual patient based on the intraoral scan, facial scan, cone beam computed tomography, and jaw motion trajectory, which helped record centric relation and determine a proper occlusal vertical dimension in a virtual environment. The therapeutic position could be exported directly to the dental computer-aided design software for digital waxing design with a facial scan. The 4D virtual patient was also used to verify the functional and esthetic outcomes of provisional restorations. CONCLUSIONS: This novel approach digitized the process of determination, delivery, and double-check of maxillomandibular relation, thus contributing to the establishment of a completely digital workflow for fixed prosthetic rehabilitation. CLINICAL SIGNIFICANCE: Registration of maxillomandibular relation, including centric relation and occlusal vertical dimension is critical to the success of prosthetic rehabilitation. Traditional procedures are complex and time-consuming, and heavily rely on the clinical experience of dentists. A fully digital approach to creating a 4D virtual patient and registering the maxillomandibular relation is established, which guides to determine a proper occlusal vertical dimension in centric relation. Digital delivery and double-check can simplify the conventional procedure and ensure that the determined maxillomandibular relation is reliable.


Assuntos
Desenho Assistido por Computador , Mandíbula , Humanos , Fluxo de Trabalho , Dimensão Vertical , Registro da Relação Maxilomandibular/métodos
16.
Clin Oral Investig ; 27(7): 4017-4028, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37247089

RESUMO

OBJECTIVES: This clinical study aimed to compare the performance of various virtual articulator (VA) mounting procedures in the participants' natural head position (NHP). MATERIALS AND METHODS: Fourteen participants with acceptable dentitions and jaw relationships were recruited in this study registered in the Clinical Trials Registry (#NCT05512455; August 2022). A virtual facebow was designed for virtual mounting and hinge axis measurement. Intraoral scans were obtained, and landmarks were placed on each participant's face to register the horizontal plane in NHP. Six virtual mounting procedures were performed for each participant. The average facebow group (AFG) used an indirect digital procedure by using the average facebow record. The average mounting group (AMG) aligned virtual arch models to VA's average occlusal plane. The smartphone facial scan group (SFG) and professional facial scan group (PFG) used facial scan images with Beyron points and horizontal landmarks, respectively. The cone-beam computed tomography (CBCT) scan group (CTG) used the condyle medial pole, and horizontal landmarks were applied. The kinematic facebow group (KFG) served as the control group, and a direct digital procedure was applied using a kinematic digital facebow and the 3D skull model. Deviations of the reference plane and the hinge axis between the KFG and other groups were calculated. The inter-observer variability in virtual mounting software operation was then evaluated using the interclass correlation coefficient (ICC) test. RESULTS: In virtual condylar center deviations, the CTG had the lowest condylar deviations. The AFG showed larger condylar deviations than PFG, SFG, and CTG. There was no statistically significant difference between the AFG and the AMG and between the PFG and the SFG. In reference plane deviations, the AMG showed the largest angular deviation (8.23 ± 3.29°), and the AFG was 3.89 ± 2.25°. The angular deviations of PFG, SFG, and CTG were very small (means of each group < 1.00°), and there was no significant difference among them. There was no significant difference between the researchers, and the ICC test showed moderate to excellent reliability for the virtual condylar center and good to excellent reliability for the reference plane in the operation of the virtual mounting software. CONCLUSIONS: CBCT scan provided the lowest hinge axis deviation in virtual mounting compared to average mounting, facebow record, and facial scans. The performance of the smartphone facial scanner in virtual mounting was similar to that of the professional facial scanner. Direct virtual mounting procedures using horizontal landmarks in NHP accurately recorded the horizontal plane. CLINICAL RELEVANCE: Direct digital procedures can be reliably used for virtual articulator mounting. The use of a smartphone facial scanner provides a suitable and radiation-free option for clinicians.


Assuntos
Articuladores Dentários , Oclusão Dentária , Humanos , Registro da Relação Maxilomandibular/métodos , Maxila , Reprodutibilidade dos Testes
17.
Rev. Cient. CRO-RJ (Online) ; 8(1): 28-34, Jan.-Apr 2023.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1512079

RESUMO

Objetivo: avaliar alterações dimensionais em marcas de mordidas simuladas em um tipo de queijo e de goiabada com o decorrer do tempo. Materiais e Métodos: mordidas foram simuladas em 20 amostras-padrão formato retangular nas medidas 30 x 60 mm e espessura de 20 mm de queijo tipo muçarela (n=10) e goiabada (n=10) com a utilização de um manequim odontológico montado em oclusão normal e acoplado à máquina universal de ensaios mecânicos. Amostras foram mantidas em superfície de vidro em ambiente com temperatura e umidade controladas seguida da aferição das distâncias intercaninas das marcas a cada hora com auxílio de paquímetro digital, durante 120 horas de experimentação. A temperatura e umidade mantiveram-se constantes durante todo período. As medidas obtidas foram estatisticamente analisadas por meio dos testes de Friedman, de Wilcoxon, coeficiente de correlação de Spearman e a partir da análise de regressão linear simples. O nível de significância adotado foi de 5%. Resultados: os alimentos testados mantiveram o padrão das medidas lineares nas primeiras quatro horas (p>0,05). Após esse período, ocorreu uma deformação progressiva, levando ao aumento significativo das medidas (p<0,05). Conclusão: a marca de mordida em queijo tipo muçarela e goiabada apresentou-se dimensionalmente estável nas primeiras quatro horas, pós mordida. Após esse período, as marcas já não apresentaram características favoráveis para serem utilizadas como registro para fins de comparação.


Objective: to evaluate dimensional changes in simulated bite marks in a type of cheese and guava paste over time. Materials and Methods: Bites were simulated on 20 standard rectangular samples. in the measures 30 x 60 mm and thickness of 20 mm of mozzarella cheese (n=10) and guava paste (n=10) using a dental manikin mounted on normal occlusion and coupled to the universal mechanical testing machine. The samples were kept on a glass surface in an environment with controlled temperature and humidity , followed by the measurement of intercanine distances of the marks, every hour, with the aid of a caliper digital, during 120 hours of experimentation. The temperature and humidity remained constant throughout the period. The measurements obtained were statistically analyzed using the Friedman, Wilcoxon, Spearman's correlation coefficient and from the linear regression analysis simple (IBM SPSS. 21.0, 2012, Armonk, NY: IBM Corp.). The level of significance adopted was 5%. Results: the foods tested maintained the pattern of linear measurements in the first four hours (p>0.05). After this period, a progressive deformation occurred, leading to the significant increase in measurements (p<0.05). Conclusion: the bite mark in mozzarella cheese and guava paste it was dimensionally stable in the first four hours, post-bite. After this period, brands no longer have favorable characteristics to be used as a record for comparison purposes.


Assuntos
Humanos , Mordeduras Humanas , Registro da Relação Maxilomandibular , Alimentos , Odontologia Legal
18.
J Oral Rehabil ; 50(7): 617-626, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36943389

RESUMO

BACKGROUND: Evaluating occlusal contacts during maximum intercuspation is one of the requirements for guiding clinicians during occlusal corrections and has been a topic of considerable importance for researchers over many decades. OBJECTIVE: This systematised review intends to evaluate the average number of occlusal contacts present in dentate adults, as documented within the dental literature over the past four decades (1980s-2022). METHODOLOGY: Electronic searches were conducted in three databases (PubMed, Livivo and Ovid) using a combination of search words. RESULTS: A total of 651 records were identified through PubMed and another 37 records through Livivo and Ovid databases. After eliminating duplicates and irrelevant records, 168 records were screened. Full texts of 61 articles remained, out of which 18 relevant papers that presented occlusal contacts in quantifiable value were considered. Various occlusal indicators, such as articulating paper, wax sheets, shimstock foil, impression material, gnathodynamometers and digital occlusal analysis systems, were used to evaluate occlusal contacts. The number of occlusal contacts widely ranged from 11 to 70. These variations likely depends upon the type and technique of occlusal indicator used, diversity among sampled populations and differing data collection procedures. CONCLUSION: Different methods of identifying occlusal contacts in the intercuspal position yield different numbers and patterns of contacts, depending on the nature and physical properties of the indicators used.


Assuntos
Materiais para Moldagem Odontológica , Oclusão Dentária , Humanos , Adulto , Registro da Relação Maxilomandibular/métodos , Mandíbula
19.
J Indian Prosthodont Soc ; 23(1): 65-70, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36588377

RESUMO

Aim: The fabrication of an accurate prosthesis depends mainly on precise recording of the maxillo-mandibular relationship of the patient and transferring it to the articulator. BDIMPRESS is a new thermoplastic material that has been proposed as a potential material to be used as an inter-occlusal registration, but there has been no literature evidence regarding its application as a bite registration. The main purpose of this study is to evaluate and compare the dimensional stability, detail reproduction, and compressive resistance of new interocclusal recording material with other two commonly used materials. Settings and Design: In Vitro Comparative study. Materials and Methods: The study was conducted according to ADA Specification standards of testing for dimensional stability, detail reproduction and compressive resistance. Specimens were prepared for three different materials (Thermoplastic resin, Polyvinyl siloxane, and Bis- acrylic) with 12 samples each. Statistical Analysis Used: One way ANOVA was done for statistical analysis. Results: Polyvinyl siloxane material was dimensionally stable (mean at 1 hr: 24.928 mm; 24 hrs: 24.919 mm & 48 hrs: 24.912 mm) followed by Bis- acrylic material (mean at 1 hr: 24.851 mm; 24 hrs: 24.825 mm & 48 hrs: 24.815 mm). On one way ANOVA, strong significance was observed between groups (P = 0.00). Thermoplastic resin showed higher amount of detail reproduction with 10 (out of 12 samples) samples showing satisfactory results. While bis- acrylic material showed the least compressive resistance (Strain %: 0.484%; Displacement- 0.0990mm). One-way ANOVA showed presence of significance between the groups (P = 0.024). Conclusion: Polyvinyl siloxane showed superior dimensional stability, thermoplastic resin showed better detail reproduction and bis- acrylic showed high resistance to compression over other materials.


Assuntos
Polivinil , Siloxanas , Humanos , Registro da Relação Maxilomandibular/métodos , Resinas Vegetais , Polimetil Metacrilato
20.
Beijing Da Xue Xue Bao Yi Xue Ban ; 55(1): 101-107, 2023 Feb 18.
Artigo em Chinês | MEDLINE | ID: mdl-36718696

RESUMO

OBJECTIVE: To verify the consistency between the digital manufacturing simple intraoral Gothic arch-tracing device and the traditional intraoral Gothic arch-tracing device in determining the centric relation of complete dentures restoration. METHODS: Ten outpatients with edentulous jaws were selec-ted, and the centric relation of the patients was determined by digital manufacturing of simple intraoral Gothic arch-tracing device (T1) and traditional intraoral Gothic arch-tracing device (T2); the difference of clinical operation time between the two methods was recorded; the upper and lower edentulous jaw plaster models were scanned with two kinds of centric relation, the Standard Triangle Language (STL) files imported into Geomagic studio software to apply the best fitting of multiple points of the both upper jaw models, the fitted STL files imported into the 3 shape viewer software, and the maximum position deviations of the vertical, labial (buccal) and lingual directions of the mandibular midline area and molar areas in T1 and T2 groups measured. During the clinical complete dentures try-in, we observed whether there was midline deviation in the mouth of T1 group and T2 group, and whether the occlusion of posterior teeth was stable or not. RESULTS: The mean time spent on determining the centric relation of T1 and T2 groups was (41.90±2.64) min, (57.50±2.37) min respectively. Paired t test was conducted in the two groups, P < 0.01 with significant statistical difference; The mean maximum position deviation between T1 group and T2 group of the midline mandibular region in labial lingual direction was (0.32±0.14) mm, that was (0.40±0.23) mm in vertical direction; the mean maximum position deviation of molar area in buccal lingual direction was (0.35±0.23) mm and that was (0.33±0.20) mm in vertical direction. In the vertical and horizontal directions, the maximum position deviation of mandibles between group T1 and group T2 was controlled within 0.5 mm. In the process of clinical complete dentures try-in, there was no deviation from the center line of dentures. There was not warping, swinging and other poor stability phenomena in T1 and T2 groups. CONCLUSION: The digital manufacturing of simple intraoral Gothic arch-tracing device can be used to determine the centric relation of complete dentures, which can not only save time of clinical operation, but also ensure the accuracy of the centric relation.


Assuntos
Arcada Edêntula , Boca Edêntula , Humanos , Relação Central , Registro da Relação Maxilomandibular/métodos , Prótese Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...